Drinking-water monitoring from intake and treatment to the distribution network, preserving the process stages and instrument selections shown in the original Thermo Scientific application diagram.

  1. Raw-water intake → ozone or chlorine pretreatment
  2. Rapid mixing → flocculation → sedimentation
  3. Filter beds → chlorination → clear-water storage
  4. Booster pumping → water tower → distribution network → consumers
  5. Filter-bed backwash wastewater

Raw water

AquaPH differential pH; AquaTurb high-range turbidity; 2240 ammonia-nitrogen monitor; 3131 permanganate-index monitor; Chlorine XP residual/total chlorine; five-parameter water-quality monitoring system; AquaCD conductivity.

Flocculation and sedimentation

AquaPH differential pH; AquaTurb high-range turbidity.

Filtration monitoring and purification

AquaClear low-range turbidity; AquaPH differential pH; AquaTurb high-range turbidity.

Disinfection and replenishment

Chlorine XP residual/total chlorine; AquaClear low-range turbidity; 2109XP fluoride; AquaOZ ozone; 2210AM ammonia-nitrogen monitor.

Distribution network

Chlorine XP residual/total chlorine; AquaClear low-range turbidity; AquaPH differential pH; AquaCD conductivity.

View original source diagram (Chinese)Original Chinese application diagram, with English information provided above