System / O₂ · CO · process gases
HN-LQL-X
Sample conditioning and gas analysis for challenging raw coal gas containing tar, dust and moisture.
Tianlan Optoelectronics
In-situ NOₓ and Oxygen Analysis
Measure NOₓ and oxygen at the process, with distributed monitoring for a clearer view of SCR conditions.

The supplied SCR material describes direct NOₓ and O₂ measurement using a zirconia sensing approach. Multiple measurement positions can help describe the distribution across the duct.
Sensor selection, operating conditions and response criteria belong in the technical specification. This page covers the NOₓ/O₂ configuration described in the supplied material.
| Detector | Dual-cell thick-film zirconia detector |
|---|---|
| NOₓ ranges | 0–100 ppm or optional 0–1,500 ppm |
| O₂ range | 0–21.00% |
| Linearity error | NOₓ: ±1.5% of full scale; O₂: ±1.5% of full scale |
| Repeatability | NOₓ: ±1.5% of full scale; O₂: ±1.5% of full scale |
| Stability over 7 days | NOₓ: ±2.5% of full scale; O₂: ±1.5% of full scale |
| Response time | T90 <10 seconds after full warm-up |
| Described flue-gas application | Continuous measurement in SCR flue gas at 350–450 °C |
|---|---|
| Mounting arrangement | Direct duct or stack mounting; measurement positions selected for each control zone |
| Plant interface | RS-485 or 4–20 mA signals to the DCS |
Ask the team for the current technical data sheet and application-specific configuration.
The updated brochure covers distributed in-situ measurement and SCR control applications, with RS485 or 4–20 mA connection to the DCS.
Product brochure