PM-2620 Particulate CEMS for Dry Flue Gas

PM-2620 Particulate CEMS for Dry Flue Gas

Overview

The PM-2620 analyzer meets the requirements of EN 14181 and can measure concentrations of particulate matter from incineration, combustion processes and other industrial emissions. Because of its 0-15 mg/m3, the PM-2620 analyzer can be applied to emission monitoring at high and low concentrations. The analyzer can also measure higher concentrations of dust discharges in power plants, cement plants, metal smelters, etc., by virtue of the dynamic mass range function.

The introduction of a very convenient one-sided pipe installation, without the need for a second luminum, and the fact that all PM-2620 measurement components are located outside the pyrotechnic, does not affect process gases and significantly reduces the risk of contamination of the system. When the blow-down function fails, the system automatically isolates the light and avoids contamination of the measuring components. In addition, smoke was prevented from entering the analyzer when calibration and maintenance were carried out.

PM-2620 is a unit for large and medium-sized pyrotechnics that allows for high-precision, low-precision maintenance, flexible systems and analyzers that meet international standards. As an alternative to obscurity, it can measure mass concentrations (mg/m3) and can be calibrated for emission monitoring at lower concentrations.

Features

Using laser backscatter technology, minimum detection is less than 1 mg/m3

Available for low concentration emission monitoring, with certified range of 15 mg/m3

Manual zero and spot testing;

Full integrated optical systems, with automatic functional checks;

The blow-down failure auto-alerts and automatically triggers the built-in optical isolation (optional).


Technical Specifications

:

Process/Apply Conditions


Applicability

For measuring non-condensation flue gas components

Frozen temperature

-20~+250℃(Optional tops400℃)

Smoke pressure.

±20mbar

Smoke diameter

1-10m

The flue gas.

Non condensation

Explosive-proof level

Zone 2(Optional)

Firework Connection

DN80 PN10/PN16Frank.

Measuring information


Type of measurement

Laser backscatter method

Resolution

0.1mg/m3

Response Time

2s

Authentication scale

0-15mg/m3

Dust concentration

<1 to 500 mg/m3

Sensor Options


Sensors

PM-2620Independent compact.

Sensor material

316l

Dimensions

L454×H217×D204

Protection level

IP65

Power supply

100-240V ACor24V DC

I/O

1×Modbus RS485, 2×Relay outputs

1×4-20mA output, 1×Digital input

Manual calibration

Single compact unit, or calibration unit of five slices (optional)