410i Carbon Dioxide (CO2) Analyzer
The analyzer analyses CO2 concentrations in the gas stream using advanced non-dispersible infrared spectroscopy technology (NDIR) and optical fixed-band interference filters, as well as quantum detectors. In addition, extended operating ambient temperature ranges provide excellent performance within wider concentrations and maintain good linear relationships across the range Main functions: Advanced NDIR technology User-optional reporting function Extended ambient temperature range Excellent performance in a wider concentration. Linearness through the entire range Configureable oxygen sensor modules: The 410i analyzer, equipped with an oxygen sensor with magnetic sensor technology, provides an extension function in CO2 pollution source monitoring, with the ability to read and report oxygen concentrations (up to 100 per cent) in sample streams. In addition, the programming function allows users to correct CO2 readings through oxygen content in the sample gas. Optimal O2 concentrations can be used as correction factors. (e.g. CO2 correction to 6% O2 or any other percentage. It's not a good idea. ISeries' Advantage: Efficiently remotely accessed Ethernet connections Large-size screens and enhanced user interfaces with editable shortcuts Additional memory flash memory software to store more data and downloads from users Enhanced e-design optimizes product interoperability Improved layout of more easily maintained components voltage 110/115/220/240VAC Weight 39 lb. Weight ( Metric )17.7kg Description of carbon dioxide gas analyzer Flow Rate 1L/min. Input standard/high concentration: 16-digit input (coding), 8 0 Output Standard / High concentration : Optional voltage 、RS232/RS485、TCP/IP、10 State relays 、 The blackout instructions. ( Plot )。0-20 or 4-20mA Sequester current output ( Selection ) Accurate readings ±1.0% 90 seconds response time (average time 30 seconds) Range drifts high concentrations :<2.0% Read (7 Day ), Standard :<0.5% Working temperature (English) 41°-113°F Working temperature ( Metric )5-45°C Zero drift: high-concentration version ±40 ppm; standard version ±1.0 ppm Zero noise high concentration :10ppm( Average time 60 sec ); Standard :0.1ppm( Average time 300 sec ) High detection limit concentration :20ppm( Average time 300 sec ); Standard :0.2ppm( Average time 300 sec ) Measured gas carbon dioxide Item description 410i carbon dioxide gas analyzer Preset measurement range high concentration :0 to 0.5、1、2、5、10、20、25%; Standard :0 to 200、500、1000、2000、5000 and 10,000ppm Certification/compliance ETS, CSA, UL, CE Unit Size Each |