The effect of some elements of the flue gas analyzer test on the results of the soot test should be noted in the soot test process, first of all to ensure a smooth flow of gas in the pipe and the use of pumps to sample the flue gas, which, if not matched, would have a significant impact on the results of the tests, which would have been less rapid if the sampling pump had been smaller than the gas flow in the flue, and obviously the results of the soot test would have been lower. If the flow of gas within the pipe is small and the flow of the sample pump is high, the result would be the opposite. Second, since the filters that are now commonly used are fibre filters of glass, with the mandatory application of temperature limits, which can only be applied with talent up to 400 degrees, the boiler burns at too high a temperature, making the filters too hot.
2021-10-24
0
0
0
-
A description of how the carbon monoxide analyzer model is selected: determining the use of field condition parameters first to analyse the form of use of the instrument scheme (portable, online), whether or not to consider blast protection, the components of carbon monoxide (-species or more), the flow of power, the approximate extent of the content, temperature and humidity, the presence of water vapour, the presence of dust and the presence of corrosive carbon monoxide, etc., will influence the analysis of detection results. Second, there is also a need to communicate with the manufacturer on signal output, current output, alert upper and lower limits, the need for network interfaces, wireless transmission, etc., switch output, etc. So it's important that the carbon monoxide analyzer provide the real work environment and parameters, and then, with these basic conditions, carbon monoxide
2021-10-16
0
0
0
-
How does the carbon monoxide analyzer fit? The carbon monoxide analytical instrument is an industrial process control instrument. The use of industrial processes, especially those in which chemical reactions are present, such as chemical plants, pharmaceutical industries, the empty industry, steel smelting, coal-chemicals, etc., is very widespread and guides process production. The selection of the carbon monoxide analyzer (system) is therefore very important, with some firms choosing the model with an occasional oversight or an attempt to be cheap having problems with the selection. The loss of normal use or the high workload of maintenance of light equipment leads to a production safety hazard. Because of the different production conditions of each plant, the types of carbon monoxide that are analysed and tested are very numerous, and different carbon monoxide, the selection needs to be based on actual I and actual needs. That's right.
2021-10-16
0
0
0
-
An oxygen-containing instrument for measuring the flue gas is referred to as a portable flue gas analyzer. The commonly used portable flue gas analyzers are primarily thermal magnetic and zirconium oxide. (1) Thermal magnetic oxygen analyzer of the portable flue gas analyzer is based on the physical properties of particularly high magnetic rates of oxygen in the flue gas composition to determine oxygen content in the flue gas. Oxygen is a magnetic gas (which can be referred to as a magnetic gas from magnetic sites) and is drawn into the magnetic field in an uneven manner, leading to a stronger magnetic field. The presence of heaters at the site reduces magnetic field pull and discharges from the magnetic field, driven by unheated oxygen molecules with high back magnetic rates, resulting in a heat-magnetic convection or magnetic wind phenomenon. After measuring the size of the magnetic wind, at the required pressure, temperature and flow of the air sample.
2021-10-09
0
0
0
-
The portable flue gas analyzer, which uses heat-heated flame organization detectors (HFID) to measure total hydrocarbons (including THC, VOC, TOC, NMHC), is a standard measurement technique that fully complies with the regulations. Portable flue gas analyzers have a wide range of applications, ranging from smoke boilers to combustion stoves to high-concentration solvent users. The outstanding relevance of lipids, alcohols, esters, ketone and aromatic compounds provides a solid method for detecting total hydrocarbon concentrations. It is based on the use of hydrogen and air burning flames, when organic compounds enter flames burned with hydrogen and oxygen, when chemical ionizing occurs at high temperatures and when ionizing occurs several orders of ion above the base current. The directional effect of the high-voltage field is to form an ion flow, with a weak ion flow passing through high resistance.
2021-10-09
0
0
0
-
In recent years, as the economic level of the country has risen year by year, and as people progress in their daily lives, the environment has been excessively polluted and the water has blackened and odoured. This not only destroys people ' s daily environment, but also endangers their health, and the State attaches great importance to environmental protection. In order to save the living environment on which people depend and to deal with water pollution, and in response to calls for national environmental protection, water quality monitoring has become a very necessary process in the context of the water environment, for which water quality detection instruments provide strong guarantees. Water quality detection instruments have played a leading role in the rise of future malls and demand for future malls has grown rapidly. As the epidemic has affected us, and as all the negative aspects of our lives have emerged, we should step up our efforts to uphold hygiene and sanitation, especially water quality and environmental pollution.