|
GR52M Portable FID Analyzer
GR52M portable FID analyzer, SmaFID, is a mobile analyzer for the measurement of organic carbon (VOCs). It is converted from a flame ion detector to a telecommunications number for hydrocarbon concentrations in the gases measured. A CHO ion with a CH structure occurs at high temperatures with hydrocarbons in combustion by a burner in an electric field environment of hydrogen gas and air without VOC. The corresponding VOC values were obtained by testing the ion flow. The measured values can be displayed on the large LCD screen in units of ppm or mgC without a second conversion. GR52M portable FID analyzer, where the measured gas is sampled by an internal membrane pump installed with a heated measuring sensor, some of the gas enters the FID detection room for analytical measurements, while the other part is excreted by side roads. The instrument measures the pressure stability of the gas during the pressure control analysis. All components exposed to detected gases are heated to 200°C. So SmartFID can be applied to almost all industrial engineering applications without being affected by the condition. The instruments are equipped with automatic fire control detectors, measurements of air pumps and pressure controls. GR52M portable FID analyzer -- technical parameters Hydrocarbons, chlorinated hydrocarbons Measurement principles Flammation Ion detector (FID) Measurement range: 5 optional ranges/auto-interchanges, with a range of free editing (Relative to C3H8) Standard: 0–10 ppm to 0–10 vol.% Optional : 0~1 ppm Present. 0~1 Vol.% Test limit values ≤1.5% Measuring Process Value Linear ±1.0% of the selected range Duplicate ≤1.0% At very high temperatures and pressure. Zero-point drift ≤ of range per month 0.5% Measured drift ≤ A weekly process value. 2.8% Oxygen interference. <1.8% Relative to 80ppm C3H8 Preheating time 25 min Response Time T90 < 1.5 s GR52M Portable FID analyzer - Measuring conditions: Pressure: atmospheric pressure ±0.05 bar Temperature 0–300°C Flow Approximately 1.2 l/min Airway interface Exterior 6mm stainless steel interfaces or quick interfaces Gas consumption: Fuel gas Hydrogen ,5 Category , Residual hydrocarbons <0.5ppm, Pressure :3bar Consumption during continuous operation: 1.2 l/h; alternatively, H2/He mixed gas: approximately 2.4 l/h Calibration of air It's in a scale range. 80%( Common propane ), Balance gas to air. Pressure :3bar, calibration time consumption :1.6l/min (b) Internal gas pumps, carbon filters or hydrocarbon catalytic devices The interface. Fast contact. Power 115 or 230 VAC,48 Present. 63 Hz; It's working. : 350 W (when heated), usually 120 W (excluding catalytic converters) at work; 540 W (when heated), usually 150 W (including catalytic converters) at work; Weight Analytical instruments : 14 kg Dimensions 420 mm x 470 mm x 310 mm Simulation Quantities Output 2 A free-editing output 0~4 - 20mA Digital Quantities Output 3 Free-edited Contacts, 250 V AC 1 A Based on standard CE, EMV, VDE 0701, DIN EN 15267-3 Product characteristics :: Automatic monitoring of key tasks and parameters • Embedded microprocessor automation ● Large 5.7-inch LCD for operation and instrument status display ● User-selectable range and automatic range switching within 0–100,000 ppm / 0–160,000 mgC • An internal measurement data storage function, in XML format, to output the EXCEL format through USB • Portable aircraft boxes, which contain both fuel cylinders and cylinders • Internal heating controller controls 5 m long heating tube ● Setable Simulation Output 0/4-20mA • Network interface module :: Multilingual selection :: Reliable detection techniques validated on-site by long-term users • Low fuel consumption technologies • Low operating costs • Close design |

